====== System Five – Adding Additional Workstation ======
Please see: https://support.windwardsoftware.com/a/solutions/articles/66000491308
In order to setup System Five on an additional workstation or swap out a workstation, the following installers will need to be available. Contact Windward support to receive these installers.
- Pervasive SQL or Actian Zen 14 (typically less than 150 MB)
- Windward System Five (typically less than 250 MB)
===== Requirements =====
- Administrator permissions for the Server Windward share and all its files and sub-Folders with full Read/Write
- Typically, both System Five and Pervasive SQL installer are copied to the C:\windward\temp folder
- A mapped drive needs to be created linked to the shared “Windward” folder of the server (W: drive)
- Complete the [[preinstallation_checklist#standard_workstation_configuration|pre-installation checklist]]
===== Installation of Pervasive Client on workstation =====
For Pervasive installation, you must have Pervasive 12 or Actian Zen 14.
**1.** **Click ‘Unzip’ button** \\
{{:psql1.jpg?400|}}
**2.** **Click “Ok” button** \\
{{:psql2.jpg?400|}}
**3.** **Click ‘Install PSQL v12 SP1 Client Only’** \\
{{:psql3.jpg?400|}}
**4.** **Click ‘Next’ button** \\
{{:psql4.jpg?400|}}
**5.** **Accept & click on “Next” to proceed** \\
{{:psql5.jpg?400|}}
**6.** **Select ‘Run as a Service’ option & click Next** \\
{{:psql6.jpg?400|}}
**7.** **Leave it as ‘Complete’ then click Next** \\
{{:psql7.jpg?400|}}
**8.** **Click ‘Install’ to begin the installation** \\
{{:psql8.jpg?400|}}
**9.** **Wait until it is finished installing then click on ‘Finish’** \\
{{:psql9.jpg?400|}}
**10.** **You can now ‘Exit’ this window. You’re done installing Pervasive Client** \\
{{:psql10.jpg?400|}}
===== Installation of Windward System Five on workstation =====
- Run [Drive]:\Windward\Temp\install.exe (If a new installation file has been downloaded, use [Drive]:\Windward\Temp\s5install.exe)
- Install to C:\Windward\System5 to do a local install, do not install to a remote drive.
- Accept all other default settings. Finish installation.
- Shortcut on Workstation desktop is linked to C:\Windward\System5\Bin\systemfive.exe
This installer also comes with 2 required software installation, those will need to be installed with System Five.
* Borland Database Engine
* MSXML v3 & v4
===== Link an existing Workstation to data set =====
If you are linking to an existing dataset (i.e. from a backup, etc.)
- Launch System Five from desktop shortcut.
- Select “Link workstation to the existing networked company” and click next
- Browse to Mapped network drive location [Drive]:\System5\Data (Or where 'Data' folder has another name eg: “MyCompany”)and click next
- Assign an available terminal number and click ‘Next’
- You will then receive a message stating that “your terminal has been setup”. Click 'Finish' to continue.
===== Modifying Desktop Shortcut to prevent terminal ID change =====
- Right-click the shortcut and select 'Properties'
- In the 'Target' box, ensure that the line reads C:\Windward\System5\Bin\systemfive.exe
- At the end of that line add the command ' /Forcemachine=#' where # is the assigned terminal number
- Printer settings are terminal-specific, the above command prevents users from inadvertently changing a terminal number on a workstation thereby losing the ability to print
- Additionally, you can use the optional command 'smallsplash' to make the splashscreen smaller.
- Full target line in shortcut properties would be as follows: '[Drive]:\Windward\System5\Bin\systemfive.exe /smallsplash forcemachine=#' where # is assigned a terminal number.
- In the 'Start In' box in shortcut properties, make the entry '[Drive]:\System5\Data'. This will lock that shortcut to a specific data set (Should you have more than one ie: A Training Data Set)\\
{{:locked_live_data.jpg|}} \\
{{:locked_terminal.jpg|}}
===== Other Setup and Troubleshooting =====
There might be additional setup and/or troubleshooting needed after successfully installing System Five. You may want to refer below:
- In order to speed up some system functions, you will need to enable [[create_dsn_database_through_odbc|ODBC DSN]].
- Fixing [[windwardpos_device_error_on_windows_10|WindwardPOS Device Error]]. This error can present after installing System Five.