Line 14: | Line 14: | ||
===== Invalid Secure Device ===== | ===== Invalid Secure Device ===== | ||
- | | + | |
+ | | ||
* If they are using the Remote POS device manager, this needs to be updated on the client workstation. | * If they are using the Remote POS device manager, this needs to be updated on the client workstation. | ||
+ | |||
+ | ===== SecureDevice not Valid on Test Servers ===== | ||
+ | |||
+ | * If you are using the dsiPDCX screen prompt, the test servers operation is not valid with this device. You can temporarily switch the pinpad to a Vx805 to do the test as the operation does not actually check for the pinpad. | ||
+ | * If you are using a pinpad, please update the datacap controls as above. | ||
+ | |||
+ |