User Tools

Site Tools


faq:scanners:metrologic_series

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
faq:scanners:metrologic_series [2013/11/27 10:31 (10 years ago)] – [The Codes] swindfaq:scanners:metrologic_series [2021/04/19 20:59 (3 years ago)] (current) – [MetroLogic Barcode Scanners] kturner
Line 1: Line 1:
 ====== MetroLogic Barcode Scanners ====== ====== MetroLogic Barcode Scanners ======
 Metrologic makes a series of very popular scanners.  Most of them can be configured with the appropriate prefix by scanning the below sequence. Metrologic makes a series of very popular scanners.  Most of them can be configured with the appropriate prefix by scanning the below sequence.
 +
 +[[https://www.windwardsoftware.com/resources/shop-pos-hardware.html|SHOP FOR COMPATIBLE HARDWARE]]
  
 ==== Problem ==== ==== Problem ====
Line 34: Line 36:
 <note warning>The following codes should not be used with other brands of scanners.  At best they simply won't work, at worst you may cause your scanner to cease functioning.</note> <note warning>The following codes should not be used with other brands of scanners.  At best they simply won't work, at worst you may cause your scanner to cease functioning.</note>
  
-==== The Codes ====+===== The Codes ===== \\ 
 +These codes will work for the Honeywell Orbit MS7120 \\
  
 ^ Command ^ Scan Code ^ ^ Command ^ Scan Code ^
-^  Enter Config  |  {{http://wws5.com.au/support/ms9520/StartEndConfig.gif}} | +^  Enter Config  |  {{ :barcodescan:startendconfig.png?nolink }} | 
-^  Set Prefix  |  {{http://wws5.com.au/support/ms9520/SetPrefix.gif}}  +^  Set Prefix  |  {{ :barcodescan:setprefix.png?nolink }} | 
-^  ASCII 0  | {{ http://wws5.com.au/support/ms9520/char0.gif }} | +^  ASCII 0  | {{ :barcodescan:char0.png?nolink }} | 
-^  ASCII 0  | {{ http://wws5.com.au/support/ms9520/char0.gif }} | +^  ASCII 0  | {{ :barcodescan:char0.png?nolink }} | 
-^  ASCII 2  | {{ http://wws5.com.au/support/ms9520/char2.gif }} | +^  ASCII 2  | {{ :barcodescan:char2.png?nolink }} | 
-^  End Config  |  {{http://wws5.com.au/support/ms9520/StartEndConfig.gif}}  |+^  End Config  |  {{ :barcodescan:startendconfig.png?nolink }} |
  
-******+======******======
  
 If neither of these codes allow you to set the Ctrl+B (STX Prefix), then download the programming manual here: If neither of these codes allow you to set the Ctrl+B (STX Prefix), then download the programming manual here:
Line 51: Line 54:
  
 Once you have it, you will need to print out the Start/End Config barcode on the Introduction page, as well as the STX Prefix barcode on page 8-4 (page 46 of 116). Make sure that when you print these two pages, that you print them at the Actual size. You can not resize the pages, of have it fit to page, because that will alter the size of the barcode and it will not be scanable. Once you have it, you will need to print out the Start/End Config barcode on the Introduction page, as well as the STX Prefix barcode on page 8-4 (page 46 of 116). Make sure that when you print these two pages, that you print them at the Actual size. You can not resize the pages, of have it fit to page, because that will alter the size of the barcode and it will not be scanable.
- 
- 
  
  
faq/scanners/metrologic_series.1385577080.txt.gz · Last modified: 2013/11/27 10:31 (10 years ago) by swind