User Tools

Site Tools


topaz_t-lbk462-hsb-r_signature_capture_cloud

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
topaz_t-lbk462-hsb-r_signature_capture_cloud [2020/01/30 16:43 (4 years ago)] swindtopaz_t-lbk462-hsb-r_signature_capture_cloud [2021/05/27 14:15 (3 years ago)] (current) swind
Line 2: Line 2:
 ====== Signature Capture on Cloud With Topaz T-LBK462-HSB-R ====== ====== Signature Capture on Cloud With Topaz T-LBK462-HSB-R ======
  
-[[http://wws5.com/|{{http://wws5.com/images/topxxxgif-ani.gif  |Windward Software}}]] +<note important>This document is also available as a FreshDesk Solution Article \\ 
 +</note>
  
 ====== Sig Cap Model : T-LBK462-HSB-R  (using new Virtual Serial via USB Driver) ====== ====== Sig Cap Model : T-LBK462-HSB-R  (using new Virtual Serial via USB Driver) ======
Line 12: Line 12:
  
 We can now support the T-LBK462-HSB-R on cloud. Topaz has released a new driver to make the T-LBK462-HSB-R emulate the T-LBK462-BSB-R.  We can now support the T-LBK462-HSB-R on cloud. Topaz has released a new driver to make the T-LBK462-HSB-R emulate the T-LBK462-BSB-R. 
-The difference was: +The difference was: \\ 
-- The HSB-R was USB Only. +- The HSB-R was USB Only. \\
 - The BSB-R was USB but uses COM Port Emulation. - The BSB-R was USB but uses COM Port Emulation.
  
-Topaz’s update now the T-LBK462-HSB-R To emulate the T-LBK462-BSB-R and give it the same ability to use COM Port Emulation.+Topaz has now updated the T-LBK462-HSB-R To emulate the T-LBK462-BSB-R and give it the same ability to use COM Port Emulation.
  
 PROCESS: PROCESS:
-Server-Side Installation Steps +Server-Side Installation Steps\\ 
-1. Cloud Operations must install the Topaz SigPlus software on the Cloud Server for the client and choose the T-LBK462-BSB-R model  +1. Cloud Operations must install the Topaz SigPlus software on the Cloud Server for the client and choose the T-LBK462-BSB-R model \\ 
-2. The DemoOCX.exe will need to be copied to the user’s desktop to test the Sig Cap Device.  +2. The DemoOCX.exe will need to be copied to the user’s desktop to test the Sig Cap Device. \\ 
-Client-Side Installation Steps + 
-If your client PC is already set-up to use a Topaz pad, uninstall the SigPlus driver in “Programs and Features” before continuing.+Client-Side Installation Steps\\ 
 + 
 +If your client PC is already set-up to use a Topaz pad, uninstall the SigPlus driver in “Programs and Features” before continuing.\\
 1. Download the HSB-to-COM Driver for Topaz HSB Signature Capture Pads. 1. Download the HSB-to-COM Driver for Topaz HSB Signature Capture Pads.
-http://www.topazsystems.com/Software/download/hsbtocom.exe.  +http://www.topazsystems.com/Software/download/hsbtocom.exe. \\ 
-2. Run the HSBtoCOM.exe installer (Right click on it and run as administrator).  +2. Run the HSBtoCOM.exe installer (Right click on it and run as administrator). \\ 
-3. Accept the license agreement and Click “Next”. +3. Accept the license agreement and Click “Next”.\\ 
-4. When installation is complete, click “Finished” to close the dialog. +4. When installation is complete, click “Finished” to close the dialog.\\ 
-5. On the client, open the “Device Manager” by clicking on “Start” ? “Control Panel” ? “System” ? “Device Manager”.  +5. On the client, open the “Device Manager” by clicking on “Start” ? “Control Panel” ? “System” ? “Device Manager”. \\ 
-6. Under “Ports (COM & LPT)”, confirm that the Topaz HSB Port is listed.+6. Under “Ports (COM & LPT)”, confirm that the Topaz HSB Port is listed.\\
  
 {{ :sigcap:topaz:t-lbk462-hsb-r:picture1.png?400 |}} {{ :sigcap:topaz:t-lbk462-hsb-r:picture1.png?400 |}}
Line 87: Line 89:
 Click on Open File Location Click on Open File Location
    
-{{ :sigcap:topaz:t-lbk462-hsb-r:picture13.png?400 |}}+{{ :sigcap:topaz:t-lbk462-hsb-r:picture13.png?600 |}}
  
 In the right-hand window, right click on DemoOCX.exe and select copy from the dropdown. In the right-hand window, right click on DemoOCX.exe and select copy from the dropdown.
Line 111: Line 113:
 Back to the client: Back to the client:
 On the client workstation On the client workstation
-1. open the “Device Manager” by clicking on “Start” ? “Control Panel” ? “System” ? “Device Manager”.  +1. open the “Device Manager” by clicking on “Start” ? “Control Panel” ? “System” ? “Device Manager”. \\ 
-2. Under “Ports (COM & LPT)”, confirm that the Topaz HSB Port is still listed.+2. Under “Ports (COM & LPT)”, confirm that the Topaz HSB Port is still listed.\\
  
 {{ :sigcap:topaz:t-lbk462-hsb-r:picture18.png?400 |}} {{ :sigcap:topaz:t-lbk462-hsb-r:picture18.png?400 |}}
  
-We now need to change the assigned COM Port to the same one you noted in the Cloud environment. In my example it was COM 9. +We now need to change the assigned COM Port to the same one you noted in the Cloud environment. In my example it was COM 9.\\ 
-Double Click on Topaz HSB Port to open its properties. +Double Click on Topaz HSB Port to open its properties.\\ 
-Click on the Topaz tab +Click on the Topaz tab\\ 
-Select the COM Port you noted from the Cloud from the dropdown (again, this was COM 9 in my example). +Select the COM Port you noted from the Cloud from the dropdown (again, this was COM 9 in my example).\\ 
-Click the Set button. +Click the Set button.\\ 
-Click OK to close the window.+Click OK to close the window.\\
  
 {{ :sigcap:topaz:t-lbk462-hsb-r:picture19.png?400 |}} {{ :sigcap:topaz:t-lbk462-hsb-r:picture19.png?400 |}}
  
 You may need to click “Action” and “Scan for hardware changes” for the Device Manager screen to refresh. You may need to click “Action” and “Scan for hardware changes” for the Device Manager screen to refresh.
-Close the device manager. +Close the device manager.\\ 
-Using a text editor like Notepad, browse to C:\Windows and open the SigPlus.ini file. +Using a text editor like Notepad, browse to C:\Windows and open the SigPlus.ini file.\\ 
-In the SigPlus.ini file, change the “TabletComPort” to equal the COM Port number you just entered in Device Manager. Again, in my example it was COM9. +In the SigPlus.ini file, change the “TabletComPort” to equal the COM Port number you just entered in Device Manager. Again, in my example it was COM9.\\ 
-Click “File” and “Save” to save the changes, then exit out of the SigPlus.ini file. +Click “File” and “Save” to save the changes, then exit out of the SigPlus.ini file.\\ 
-If Windows won’t allow you to save the changes, you will need to brows to the Windows folder, right click on the SigPlus.ini file, click on security tab, click the edit button, click users, click the check box beside Full Control, click Apply, Click Yes on the security warning about changing the permissions, click OK, Click OK on the SigPlus ini properties, and now you should be able to save the changes to the SigPlus.ini file. +If Windows won’t allow you to save the changes, you will need to browse to the Windows folder, right click on the SigPlus.ini file, click on security tab, click the edit button, click users, click the check box beside Full Control, click Apply, Click Yes on the security warning about changing the permissions, click OK, Click OK on the SigPlus ini properties, and now you should be able to save the changes to the SigPlus.ini file.\\ 
-Open “DemoOCX” with the desktop shortcut or opening from C:\Windows\SigPlus\DemoOCX.exe. +Open “DemoOCX” with the desktop shortcut or opening from C:\Windows\SigPlus\DemoOCX.exe.\\ 
-Note: If DemoOCX is still open from a previous test, restart the utility. +Note: If DemoOCX is still open from a previous test, restart the utility.\\ 
-Test the signature capture here in the local workstation. If it is working correctly, sign back into the cloud environment and test it there in the DemoOCX program.+Test the signature capture here in the local workstation. If it is working correctly, sign back into the cloud environment and test it there in the DemoOCX program.\\
 If it is working in the DemoOCX program you can now open System Five in the cloud environment and providing you have setup the invoice tree and the invoice forms correctly, the Signature Capture Device will work there as well. If it is working in the DemoOCX program you can now open System Five in the cloud environment and providing you have setup the invoice tree and the invoice forms correctly, the Signature Capture Device will work there as well.
  
  
 +\\
  
 +\\
  
- +\\
- +
- +
  
 ===== System Five Setup ===== ===== System Five Setup =====
Line 170: Line 171:
  
 ---- ----
 +
 +\\
 +
 +\\
  
 ====== Setting up the Full size invoice forms to include signature ====== ====== Setting up the Full size invoice forms to include signature ======
Line 186: Line 191:
  
 Open an invoice and test. \\  Open an invoice and test. \\ 
 +
 +\\
 +
 +\\
  
 -------------------------------- --------------------------------
  
-== Steve Wind June 14 / 2019 ==+== Created by Steve Wind January 30 2020 ==
topaz_t-lbk462-hsb-r_signature_capture_cloud.1580431396.txt.gz · Last modified: 2020/01/30 16:43 (4 years ago) by swind